Made to perform, Daikin’s GTQ Series promises superior level of comfort and exceptional cooling performance. Just set the temperature you want to have and its advanced compressor will turn your place into a place you always wished for.
Salient Features
Coanda airflow

Make way for effective air circulation and efficient temperature distribution with Daikin’s Coanda airflow, designed to give the best air-conditioning experience. This function ensures cooling at corners of the room by streaming cool air upwards along the ceiling avoiding furniture or obstruction.
Econo mode

Set the limit for power consumption with Daikin's ECONO mode feature. This function enables efficient operation by limiting the maximum power consumption. This mode is one step towards Daikin's future innovation.
Good sleep off timer

You can prevent excessive cooling of the room during sleep by setting a temperature shift value. The air conditioner automatically stops after the pre-set time has elapsed. The set temperature increases by 0.5°C in 30 minutes until the total increase reaches the specified shift value.
Power chill operation

Cool down your house so fast even when outside temperature is soaring. Daikin's Power Chill operation Cools down 20% faster as compared to normal mode. Power chill ensures room temperature drops rapidly for immediate comfort.
Self-diagnosis

The machine auto detects the error and shows the related code on the remote screen. Now you can easily self diagnose the error and report it to your Daikin authorised service centre for a quick resolution.
Specification
Model name | Indoor unit | GTQ35TV16X2 | GTQ50TV16U1 | GTQ60TV16U2 | |
Outdoor unit | RQG35TV16X2 | RQG50TV16U1 | RQG60TV16U2 | ||
Power supply | 1 50Hz 230V | 1 50Hz 230V | 1 50Hz 230V | ||
(220-240V) | (220-240V) | (220-240V) | |||
Power supply intake | Outdoor unit | Outdoor unit | Outdoor unit | ||
Cooling capacity | kW | 3.35 | 5.2 | 6.4 | |
Rated | Btu/h | 11450 | 17750 | 21800 | |
Power consumption | W | 971 | 1507 | 1855 | |
Annual power consumption | kwh | 752 | 1167 | 1436 | |
ISEER | W/W | 3.45 | 3.45 | 3.45 | |
Star Rating | 2* | 2* | 2* | ||
Operating current | Cooling | A | 4.3 | 6.9 | 8.5 |
Indoor unit | |||||
---|---|---|---|---|---|
Panel colour | White | White | White | ||
Dimensions H x W x D | mm | 283 x 800 x 198 | 298 x 885 x 229 | 298 x 885 x 229 | |
(Package dimensions) | mm | (265 x 855 x 340) | (375 x 980 x 325) | (375 x 980 x 325) | |
Weight (Gross) | kg | 8 (12) | 11 (16) | 11 (16) | |
Airflow rate | m3/min. | 10.6 | 16.2 | 16.6 | |
Operation sound H/M/L/SL | Cooling | dBA | 40/35/30/-- | 45/41/35 | 47/41/35/-- |
Outdoor unit | |||||
Dimensions H x W x D | mm | 550 x 765 x 285 | 595 x 845 x 300 | 595 x 845 x 300 | |
(Package dimensions) | mm | (642 x 932 x 380) | (680 x 1035 x 410) | (680 x 1035 x 410) | |
Weight (Gross) | kg | 31 (37) | 40 (46) | 44 (50) | |
Operation sound H/L | Cooling | dBA | 51/-- | 54/-- | 56/-- |
Breaker size | A | 15 | 15 | 20 | |
Piping length | Charge-less | m | 10 | 10 | 10 |
Max. length | m | 20 | 20 | 20 | |
Max. height | m | 15 | 10 | 10 | |
Piping connection | Gas/Liquid | mm | 9.5/ 6.4 | 12.7/ 6.4 | 12.7/ 6.4 |
Operation limit | Cooling | oCDB | 19.4~50 | 19.4~50 | 19.4~50 |
Measurement conditions:
- Cooling capacity is based on: indoor temp. 27° CDB, 19° CWB; outdoor temp. 35° CDB, piping length 5 m.
- Sound levels are based on temperature conditions 1. above with 5m piping length. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
Cooling and heating capacities above are rounded off to first decimal. 1TR (Ton of Refrigeration) = ~3.517 kilowatt.